| sbgECom Library
    5.3.2276-stable
    Interface SBG Systems IMU/AHRS/INS | 
#include <sbgEComLogImu.h>
| Data Fields | |
| uint32_t | timeStamp | 
| uint16_t | status | 
| int32_t | deltaVelocity [3] | 
| int32_t | deltaAngle [3] | 
| int16_t | temperature | 
Structure that stores data for the SBG_ECOM_LOG_IMU_SHORT message.
This message is sent asynchronously and must be used for post processing.
The delta angle values are scaled based on the gyroscopes output. If any output exceeds a predefined limit, the scale factor switches from standard to high range to prevent saturation.
| uint32_t _SbgEComLogImuShort::timeStamp | 
Time in us since the sensor power up.
| uint16_t _SbgEComLogImuShort::status | 
IMU status bitmask.
| int32_t _SbgEComLogImuShort::deltaVelocity[3] | 
X, Y, Z delta velocity. Unit is 1048576 LSB for 1 m.s^-2.
| int32_t _SbgEComLogImuShort::deltaAngle[3] | 
X, Y, Z delta angle. Unit is either 67108864 LSB for 1 rad.s^-1 (standard) or 12304174 LSB for 1 rad.s^-1 (high range), managed automatically.
| int16_t _SbgEComLogImuShort::temperature | 
IMU average temperature. Unit is 256 LSB for 1°C.